Running the G1 in 110V regions (US)

Status v0 — drafted from customer-chat evidence + the reviewed Power supply 24V note, pending human review.

A frequent question from customers in 110V regions (US and similar): “Can we step up to 220 in any way? We can get something that will step up the power.”

The G1 needs a true 220–240V supply — use a split-phase 240V circuit, not a converter.

  • A standard US 120V outlet cannot run the G1 (the bed heater alone needs more than a 120V/20A circuit can deliver).
  • The correct solution is a split-phase 240V circuit — the type used for electric ovens, dryers, and dishwashers (NEMA 6-20 / 6-30 or similar).
  • A cheap step-up / step-down transformer is not a valid solution — the machine needs the full sustained 220–240V supply under load. (This corrected an earlier wiki suggestion.)

See the full electrical detail and outlet types in Power supply 24V → US / North America installation.

  1. Find an existing 240V circuit (kitchen / laundry / garage) or have an electrician install one (double-pole 20A or 30A breaker).
  2. Use the matching 240V plug for the configuration shipped.
  3. Remember the power box has two mains inputs (main + bed) that can go to two separate lines — useful for splitting the bed-heater load. See Power outlets (power box).